Generator Size for 3-, 4- or 5-Ton Central AC + Soft Starter

Compare generator sizes for 3-, 4-, and 5-ton central AC with a soft starter. Check running amps, startup demand, fuel ratings, and outlet limits.

For a 3-, 4-, or 5-ton central AC with a soft starter, start by comparing generators rated at 6,500, 7,500, or 9,000 running watts on gasoline, respectively, as examples to shortlist. Choose the size that covers your AC and other circuits while they run and can handle the compressor starting with those circuits already on. Generac standby generator sizing guide

Sizing examples by AC tonnage

The table screens the AC running load only for a 240 V single-phase system. The compressor estimates use ICM Controls’ average load ratings. Each row adds the outdoor fan (2 A) and indoor blower (3 A) from Micro-Air’s example. ICM Controls ICM870-32A specifications · Micro-Air EasyStart generator sizing examples

Central ACEstimated AC running currentExample portable generatorGasoline running / starting watts (running amps at 240 V)Propane running / starting watts (running amps at 240 V)
3 ton16 + 2 + 3 = 21 AChampion 2010776,500 / 8,125 W (27.1 A)5,850 / 7,325 W (24.4 A)
4 ton22 + 2 + 3 = 27 AChampion 2012817,500 / 9,375 W (31.3 A)6,750 / 8,400 W (28.1 A)
5 ton26 + 2 + 3 = 31 AChampion 2014179,000 / 11,000 W (37.5 A)8,100 / 11,000 W (33.7 A)

Estimate the AC running load

From the outdoor unit and indoor air handler or furnace nameplates or manuals, record the voltage, compressor RLA (run load amps), outdoor fan amps, and indoor blower amps. Add the currents as shown above when all three loads use the same voltage. If the blower uses a different voltage, give its volts and amps to your electrician as a separate load. ICM Controls ICM870-32A specifications · Micro-Air EasyStart generator sizing examples

Check startup and the loads that overlap

  1. Add up running watts. List the AC, the blower if rated separately, and any other loads you want on at the same time, such as a refrigerator, lights, or a well pump. Add their running wattages using the nameplates or manufacturer specs. Where you have only amps, record the voltage too for the electrician’s load calculation. Micro-Air EasyStart generator sizing examples · Generac standby generator sizing guide
  2. Get the startup demand with the soft starter installed. A compatible soft starter reduces the compressor’s starting surge. On the compressor nameplate, LRA stands for locked rotor amps. Give your HVAC technician the compressor and soft starter models and ask for an inrush measurement with the starter installed. Share that reading and the loads that will already be on with the generator supplier. Micro-Air EasyStart operating principle · Fluke motor inrush current guide · Generac standby generator sizing guide
  3. Check the overlap. Check the compressor’s startup demand alongside the loads already running. If a well pump can start with the compressor, have the installer account for both starts or set up load management. Confirm the proposed generator can start the AC with the planned backup loads. For whole-home standby, ask for a site survey and load calculation. Generac standby generator sizing guide

Check fuel and the home connection

Evidence and limits. Manufacturer documentation for the ICM870 series, Micro-Air EasyStart, and the three listed Champion models was checked on November 27, 2026. The table combines published estimates and specifications. No equipment testing was performed.