Illustrated title card for the guide: EasyStart Flex vs SoftStartHome vs ICM870 for Generators
comparisons

EasyStart Flex vs SoftStartHome vs ICM870 for Generators

Compare Micro-Air EasyStart Flex, SoftStartHome and ICM870 for generator backup. Check compressor fit, startup amp claims and generator wattage.

For generator backup, shortlist Micro-Air EasyStart Flex if you want Bluetooth diagnostics, or SoftStartHome for a compatible A/C up to 3 tons. With ICM870, choose the version that matches your compressor’s load amp rating (RLA). Then check whether the generator can cover A/C startup and the other loads you plan to run. Micro-Air, SoftStartHome, ICM Controls, Champion Power Equipment

Published specs at a glance

Soft starterPublished fit and featuresManufacturer’s startup-current claim
Micro-Air EasyStart FlexFor single-phase A/C and heat pump applications up to 6 tons. Bluetooth troubleshooting.Up to 75%. Micro-Air specs
SoftStartHomeFor compatible A/C units up to 3 tons.Reduces startup amperage. 3-ton product information
ICM Controls ICM870Three sizes matched to compressor RLA, with LED fault indicators.Up to 70%. 9A and 16A specs, 32A specs

Match the starter to your compressor

  1. Check the compressor type. For a variable-speed system, confirm whether the compressor is inverter-driven. Micro-Air excludes inverter-driven variable-speed compressors. Micro-Air compatibility

  2. Look up compressor RLA for the ICM870. Use the equipment manual or the rating on the unit’s service panel. ICM publishes these ranges. ICM870 sizing guide

    Compressor RLAICM870 model
    Up to 9 AICM870-9A
    9.1 to 16 AICM870-16A
    16.1 to 32 AICM870-32A

    For example, an RLA of 16 A puts a compressor in the ICM870-16A range. At 16.1 A, it falls in the ICM870-32A range. ICM warns against upsizing from the ICM870-9A or ICM870-16A to the ICM870-32A when the actual RLA is uncertain. ICM870 sizing guide

  3. Check the control board for ICM870 compatibility. ICM rules out the circuit-board and kit versions of Comfort Alert. ICM also advises against its starter on A/C units and heat pumps whose control boards detect compressor current and lock out on faults. ICM lists A/C units and heat pumps with an Emerson CoreSense module as incompatible with a direct ICM870 installation. ICM870 compatibility notes

Check the generator with your other loads

  1. List the equipment that will run together. Use each appliance’s data plate or manual to collect running wattage and, for motor loads, starting wattage. Add the simultaneous running loads. Champion’s sizing guide
  2. Check the load at the moment the A/C starts. Add the A/C’s total starting watts to the running watts of the other equipment that will already be on. Use that total as the peak load for standby generator sizing when the A/C has the highest starting wattage. Ask your installer to verify the A/C’s actual demand with the soft starter. Champion’s sizing guide
  3. Complete EasyStart’s learning process. Micro-Air prefers utility power for EasyStart’s first five compressor starts. If utility power is unavailable, Micro-Air recommends a generator that could normally start the compressor before EasyStart was installed. Switch off the generator’s economy mode during learning if it has one. Micro-Air learning guidance

For the ICM870, open Literature on the product page for the installation guide and FAQ. For SoftStartHome, use its support page to request the wiring diagram for your system. ICM Controls, SoftStartHome support

Worked example. Champion’s sizing example uses 3,500 W running and 10,000 W starting for the A/C. Its refrigerator, sump pump and lights with Wi-Fi add 800 W, 1,050 W and 500 W respectively. Champion’s worked example

Load scenarioCalculationDemand
All listed equipment running3,500 + 800 + 1,050 + 500 W5,850 W
A/C starting while the other equipment runs10,000 + 800 + 1,050 + 500 W12,350 W

Use the same calculation with your system’s actual demand. The peak total is before the sizing margin in Champion’s guide. Champion’s sizing guide

Evidence and limits. Manufacturer documentation for EasyStart Flex, the 3-ton SoftStartHome and ICM870, plus Micro-Air’s learning guidance and Champion’s standby sizing guide, was checked on November 26, 2026. Installation, commissioning and generator performance were not tested for this guide.

Sources

  1. Micro-Air EasyStart Flex product specifications
  2. SoftStartHome 3-ton product information
  3. ICM Controls ICM870-32A specifications and series sizing
  4. Micro-Air EasyStart compressor and control board compatibility
  5. Micro-Air EasyStart five-start learning guidance
  6. Champion Power Equipment home standby generator sizing
  7. ICM Controls ICM870-9A and ICM870-16A specifications