If your backup generator overloads when a single-phase AC compressor kicks on, look for a compatible soft starter. It reduces the surge of current at startup. A hard start kit boosts the compressor’s starting torque and can still leave the generator facing a surge it cannot supply. Eltwin’s comparison and SUPCO’s hard start kit
What each device changes
| Device | What it does | When to consider it |
|---|---|---|
| Hard start kit | Adds starting torque. The SUPCO SPP6 uses a start capacitor and a positive temperature coefficient (PTC) relay. | The compressor is hard to start. SUPCO SPP6 |
| Soft starter | Limits the compressor’s startup current, also called inrush current. Eltwin’s single-phase SureStart drops out of the motor circuit after startup. | The generator can carry the running load but struggles with the compressor’s starting surge. Eltwin comparison, SureStart specifications |
In its RV guidance, SoftStartUSA notes that a hard start kit may shorten the surge and may help a generator and AC pairing that was already close to working. For sizing backup power, treat a hard start kit as torque assistance. SoftStartUSA FAQ, question 43, Eltwin comparison
If the compressor also fails to start on utility power, have an HVAC technician diagnose it before buying either kit. Trane lists a failed capacitor and loose wiring among the possible causes. Trane compressor troubleshooting
What to check before buying a soft starter
- Read the AC nameplate and compressor specs. The condenser label may list starting current as locked rotor amps (LRA). Cummins sizing guide, Eltwin model specifications
- Match the compressor to the exact starter model. Eltwin lists the single-phase SureStart SS1B08-16SN at 230 V, 50/60 Hz and 8 to 16 full-load amps. Use the published range for the specific model under consideration. Eltwin model specifications
- Tell the installer about existing start-assist parts. For EasyStart, flag any factory start capacitors, PTC relays or start relays. Micro-Air installation guidance
Check what the generator has to carry
List everything you plan to power at the same time. If the AC has the highest starting wattage and the other loads are already running, compare these two totals with the generator’s ratings. For a portable generator, look for ratings above the respective totals and confirm that its output voltage matches the equipment. Cummins portable generator sizing guide
| Check | Add up | Compare with |
|---|---|---|
| AC already running | AC running watts + other loads’ running watts | Generator continuous rating |
| AC starting | AC starting watts + other loads’ running watts | Generator surge rating for a portable-generator estimate |
In Cummins’ RV example, the worksheet uses an AC rated at 1,800 running watts and 2,800 starting watts. The other loads add 1,150 running watts, giving 2,950 W while the AC runs and 3,950 W when it starts. Cummins worked example
Ask the installer to verify the AC’s starting and running wattage. For a home standby system, give the installer the full load list for a load assessment. If large appliances can start together, ask about Generac’s Load Manager, which can pause a lower-priority load when the generator nears its limit. Generac standby sizing guide
Evidence and limits. Manufacturer documentation was checked on 2026-11-26. Product details apply to the SUPCO SPP6, Eltwin SureStart SS1B08-16SN and Micro-Air EasyStart. No equipment was installed or tested for this article.